By default, mControl is configured to use the operate a PowerLinc 2414U or 2814U adapter
interface. Use the mServer.exe.xml file to adjust to use other INSTEON adapters or adjust
operational parameters.
Parameter Meaning Options
load
Whether INSTEON adapter support is
loaded and used
Y = loaded
N = not loaded
Default = Y
ConnectUsing
Which communication port the adapter is
configured to use.
¾ Select USB for PowerLinc
2414U or PowerLinc 2814U
Timer
¾ Select SERIAL for PowerLinc
2414S, Power Line Modem
2412S or 2412U
¾ Select ETHERNET for
SimpleHomeNet EZBridge
USB, SERIAL or
ETHERNET
Default = USB
COMPort
If Port is SERIAL, defines the COM port
to be used.
COM1, COM2, …
Default = COM1
IPAddr
If Port is ETHERNET, defines the IP
Address to be used.
Default = 192.168.0.65
IPPort
If Port is ETHERNET, defines the IP port
to be used.
Default = 8002
STARTUP_CHECK_LINK
During start-up, ensure that INSTEON
devices within the mControl database
are included within the PLC’s link table.
true, false
Default = true
STARTUP_CHECK_STAT
During start-up, get the current status
value of the devices within the mControl
database.
true, false
Default = true
DisableX10Control
Since the 2414x/2814x can do both
INSTEON and X10 control, use this
parameter to ignore all X10 activity.
true, false
Default = false
MapX10ToINST
Use this parameter to define X10
addresses to INSTEON addresses.
“<X10 address>=
<INSTEON addresss>”
StartingHops
The default number of mesh hops to use
in communication. This is largely a timing
factor and allows for additional delays in
talking with devices that are located
several mesh hops away from the
adapter.
You may consider setting this to 2 or 3 if
you have many devices that are located
on different phases or far away from the
INSTEON adapter.
0,1,2 or 3
Default = 1